NIRS-EEG technical info

From biophysics
Revision as of 12:03, 4 June 2025 by Lof (talk | contribs) (LEDs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Lab floor plan
Refa64
Mobita32

back to NIRS-EEG

Booth

  • Dimensions: LxWxH = 540x280x265cm

Acoustics

  • Walls: pyramid type acoustic foam
  • Floor: anti-fatigue rubber floor mat with holes

see Acoustic Materials

Rack

TDT

  • 1 RZ6 Multi-core I/O Processor (DSP)
  • 2 PM2R multiplexer
  • 1 RP2 Enhanced Real-Time Processor (DSP)
  • 2 RA16 Medusa base station

Speakers

A semi-circle of 31 Cambridge Audio Minx Min12 speakers is available for sound localization experiments:

Speaker Position Table
Speaker position (degree) Device Channel Speaker position (degree) Device Channel
0 0 0
-5 2 1 5 0 1
-10 2 2 10 0 2
-15 2 3 15 0 3
-20 2 4 20 0 4
-25 2 5 25 0 5
-30 2 6 30 0 6
-35 2 7 35 0 7
-40 2 8 40 0 8
-45 2 9 45 0 9
-50 2 10 50 0 10
-55 2 11 55 0 11
-60 2 12 60 0 12
-70 2 13 70 0 13
-80 2 14 80 0 14
-90 2 15 90 0 15

LEDs

File:Xxxxxxx.png
LED wiring scheme

%todo

The system is triggered by the RZ6 output.

Parts

LED positions

LED Position Table
LED position (degree) Device Channel LED position (degree) Device Channel
0 DCN-LED05 0
-5 DCN-LED04 1 5 DCN-LED05 1
-10 DCN-LED04 2 10 DCN-LED05 2
-15 DCN-LED04 3 15 DCN-LED05 3
-20 DCN-LED04 4 20 DCN-LED05 4
-25 DCN-LED04 5 25 DCN-LED05 5
-30 DCN-LED04 6 30 DCN-LED05 6
-35 DCN-LED04 7 35 DCN-LED05 7
-40 DCN-LED04 8 40 DCN-LED05 8
-45 DCN-LED04 9 45 DCN-LED05 9
-50 DCN-LED04 10 50 DCN-LED05 10
-55 DCN-LED04 11 55 DCN-LED05 11
-60 DCN-LED04 12 60 DCN-LED05 12
-70 DCN-LED04 13 70 DCN-LED05 13
-80 DCN-LED04 14 80 DCN-LED05 14
-90 DCN-LED04 15 90 DCN-LED05 15

EEG

  • 32 channel water-based electrode system (TMSI, Mobita), including headcap(s)
  • 72 channel REFA, including headcaps in 3 different sizes (TMSI)
  • 16 channel REFA (TMSI)
  • ring electrodes including separate caps for combined measurements with NIRS
  • TMSI Polybench recording software

NIRS

  • 2 x 24 channel system (Oxymon, Artinis) each consisting of 8 transmitters and 4 receivers (splitted fibers)
  • sampling rate up to 250 Hz
  • 8 AD channels (according to Artinis, they only sample at the rate of all other channels. Care needs to be taken, if sampling at low rates. Present your triggers for longer durations then)
  • Oxysoft recording software

Disposables

For the preparation of the subjects you need all types of disposables like alcohol, lotion, cotton pads, electrolyte gel, etc... You can find information about these items in NIRS-EEG lab disposables, and also info where to order them when needed.

Kitchen

EEG/NIRS kitchen

A small kitchen is available for washing the hair of the subject and for cleaning caps and other equipment afterwards.

FIRST AID (EHBO)

Above the kitchen on the right there is a FIRST AID-kit on the wall.