NIRS-EEG lab

From biophysics
Revision as of 10:40, 15 June 2023 by Lof (talk | contribs)
Jump to navigation Jump to search

Experimental information

  • If you wanna book the NIRS-EEG Lab, please use Google Calendar.
  • Please, take notes in the lab journal about experiments that have been run
  • Use protocols for your study/experiments/pilots

Prepared NIRS experiments

  • Basic finger tapping experiment (blocked)
  • Mapping experiments (blocked)
  • Auditory oddball experiment (tones, event-related)

Prepared EEG experiments

  • Frequency oddball
  • Spatial oddball

Basic NIRS analysis

Besides Marc's scripts for all steps during NIRS data analysis, you can start using the fieldtrip toolbox http://www.fieldtriptoolbox.org/development/nirs. Here is a general pipeline of what you may wanna do with your NIRS data.

  • read raw data (.oxy3) recorded with the oxymon
  • read trigger information from AD channels
  • define your trial (pre- and poststimulus interval, event code)
  • apply a filter
  • segment continuous data into trials (epoching)
  • convert data, i.e. changes in optical density to concentration changes
  • average data per condition/event
  • perform baseline correction
  • plot single channels or a whole grid
  • More things to do/program: do a reference channel subtraction, plot a topomap

Basic EEG analysis (event-related averaging)

Acquired data using the Polybench Software (TMSI) can be read into Matlab using tms_read(Filename.Poly5) provided by TMSI. Further analysis could for example be run with Fieldtrip (http://www.fieldtriptoolbox.org) or EEGLab (http://sccn.ucsd.edu/eeglab/).

  • reformat raw data structure to be compatible with the output of fieldtrip preprocessing
  • readout trigger/event information from the trigger channel
  • define your trial (pre- and poststimulus interval, event code)
  • segment continuous data into trials (epoching)
  • detect and remove artifacts
  • filtering
  • average data per condition/event
  • correct baseline
  • prepare channel layout once depending on the used electrode cap (for correct plotting)
  • plot single channels, all channels, or topographic distribution (for a specified time interval)

Technical information

TDT

  • 1 RZ6
  • 1 RP2
  • 2 RA16 (medusa)
Refa64
Mobita32

EEG

  • 32 channel water-based electrode system (TMSI, Mobita), including headcap(s)
  • 72 channel REFA, including headcaps in 3 different sizes (TMSI)
  • 16 channel REFA (TMSI)
  • ring electrodes including separate caps for combined measurements with NIRS
  • TMSI Polybench recording software

NIRS

  • 2 x 24 channel system (Oxymon, Artinis) each consisting of 8 transmitters and 4 receivers (splitted fibers)
  • sampling rate up to 250 Hz
  • 8 AD channels (according to Artinis, they only sample at the rate of all other channels. Care needs to be taken, if sampling at low rates. Present your triggers for longer durations then)
  • Oxysoft recording software