The Head Coil Frame is part of the [[EM Field Head Tracking System specifications|Head Movement Tracking System]]. It consists of a EMF pickup coil and a pointing rod with a red led.
 +
 +
{| class="wikitable"
 +
! Specification
 +
! Details
 +
|-
 +
| Frame
 +
| Unknown
 +
|-
 +
| Led
 +
| 3 mm Red Laser, 1000 Ohm in series
 +
|-
 +
| Laser Connection
 +
| 180cm cable with USB-A
 +
|-
 +
| Power supply LED
 +
| via USB
 +
|-
 +
| Rod Material
 +
| RVS 3.0x0.25mm
 +
|-
 +
| Rod Length
 +
| 30 cm
 +
|-
 +
| Coil Material
 +
| 191 cm, 0.5 mm coated copper
 +
|-
 +
| Coil Diameter
 +
| 32 mm
 +
|-
 +
| Coil Windings
 +
| 19
 +
|-
 +
| Coil Flux Area
 +
| 152 cm²
 +
|-
 +
| Coil Connection
 +
| coax 80 cm, BNC connector
 +
|}

Revision as of 15:06, 14 December 2023

Head Coil Auditory Sphere Lab

Description

The Head Coil Frame is part of the Head Movement Tracking System. It consists of a EMF pickup coil and a pointing rod with a red led.

Specification Details
Frame Unknown
Led 3 mm Red Laser, 1000 Ohm in series
Laser Connection 180cm cable with USB-A
Power supply LED via USB
Rod Material RVS 3.0x0.25mm
Rod Length 30 cm
Coil Material 191 cm, 0.5 mm coated copper
Coil Diameter 32 mm
Coil Windings 19
Coil Flux Area 152 cm²
Coil Connection coax 80 cm, BNC connector