Categorie | Specificatie | Beschrijving |
---|---|---|
Inputs en Outputs | Audio Inputs | 2 analogue audio inputs |
Audio Outputs | 4 powered audio outputs | |
Input Connectors | Balanced inputs, XLR connectors | |
Output Connectors | Euroblock output connectors | |
Additional Outputs | Stack outputs on all models | |
Amplifier specifications | Power Output | 1 Channel @ 4Ω: 80 WRMS, 1 Channel @ 8Ω: 50 WRMS, All Channels @ 4Ω: 55 WRMS, All Channels @ 8Ω: 40 WRMS, 1 Bridged Channel @ 8Ω: 117 WRMS |
Frequency Response | 20Hz - 30kHz (-1 dB) | |
THD+Noise @ 1kHz Full Power | <0.02% | |
Intermodulation Distortion | 50Hz & 7kHz, 4:1: <0.02% | |
TIM 100 | <0.05% | |
S+N/N 20Hz - 20kHz @ 1W/4Ω | >90dB | |
Damping Factor | >160 | |
Slew Rate | ±10V/µs | |
Channel Crosstalk @ 1kHz | >60dB | |
Input Sensitivity / Impedance | 0dBV/>20kΩ | |
Elektrical Specifications | Mains Voltage | See characteristics on the back of the unit |
Power Consumption (Max Output) | 524VA | |
Fysical Specifications | Dimensions | 482.6x88x391mm |
Weight | 9.5kg | |
Other Features | Input Sensitivity Controls | Individual controls with sealing option to avoid unwanted manipulation |
Signal Indicators | Signal presence (SP) and CLIP indicators for each channel | |
Input Channels Feature | Link switch for superior versatility | |
VCA Volume Control | Independent VCA (EUROBLOCK) volume remote control port for each input channel, compatible with 0-10 V signal and WPm series wall panels | |
Cooling System | Noiseless convection cooling (80 and 150 W models), Dual Slope Controlled Fan system (MPA4-400R) | |
Protection Mechanisms | Protection against shorting, DC at the outputs, and overheating |