Latest revision as of 14:08, 14 December 2023
Description
The Head Coil Frame is part of the Head Movement Tracking System. It consists of a EMF pickup coil and a pointing rod with a laser projected dot.
Specification | Details |
---|---|
Frame | Bollé Contour Safety Glasses |
Laser | Red |
Laser Connector | Lemo FFA.0S.304 |
Rod Material | RVS 3.0x0.25mm |
Rod Length | 30 cm |
Coil Material | 340 cm, 0.5 mm coated copper |
Coil Diameter | 35 mm |
Coil Windings | 31 |
Coil Flux Area | 298 cm² |
Coil Connector | BNC |